Flow-injection sandwich ELISA for bioprocess monitoring

Zur Kurzanzeige

dc.identifier.uri http://dx.doi.org/10.15488/1996
dc.identifier.uri http://www.repo.uni-hannover.de/handle/123456789/2021
dc.contributor.author Rhee, Jong Il
dc.contributor.author Hagedorn, Jörg
dc.contributor.author Scheper, Thomas
dc.contributor.author Schugerl, Karl
dc.date.accessioned 2017-10-10T07:51:07Z
dc.date.available 2017-10-10T07:51:07Z
dc.date.issued 1999
dc.identifier.citation Rhee, J.I.; Hagedorn, J.; Scheper, T.; Schugerl, K.: Flow-injection sandwich ELISA for bioprocess monitoring. In: Journal of Automated Methods & Management In Chemistry 21 (1999), Nr. 4, S. 121-125. DOI: https://doi.org/10.1155/S1463924699000140
dc.description.abstract A fully automated flow-injection immunoassay based on sandwich enzyme-linked immunosorbent assay (ELISA) is described for the model system: protein G-sepharose, rabbit IgG and horseradish peroxidase (HRP)-labelled protein A. After injecting rabbit IgG and HRP-labelled protein A into a cartridge containing protein G-sepharose sequentially, a mixture of hydrogen peroxide and the redox indicator, 2.2'-azino-bis(3-ethylbenzthiazoline-6-sulphonic acid) (ABTS) is passed through the cartridge. The HRP-labelled protein A bound in the cartridge is directly proportional to the concentration of rabbit IgG. The colour variation of ABTS caused during the reaction between HRP and H2O2 in the cartridge is detected photometrically. The whole assay procedure is controlled and evaluated by a computer. Rabbit Ige and HRP-labelled protein A are also detected by a fluorometer, which is introduced into the flow system. In the flow-injection sandwich ELISA, the slope of the calibration curve is 0.4491 in the range of 0 and 300 mu g ml(-1) rabbit IgG, while it is 0.1274 in the heterogeneous immunoassay. So the flow-injection sandwich ELISA system is found to be more sensitive than a heterogeneous immunoassay for the monitoring of the model protein. eng
dc.language.iso eng
dc.publisher New York, NY : Hindawi Publishing Corporation
dc.relation.ispartofseries Journal of Automated Methods & Management In Chemistry 21 (1999), Nr. 4
dc.rights CC BY 3.0 Unported
dc.rights.uri https://creativecommons.org/licenses/by/3.0/
dc.subject binding assay eng
dc.subject immunoassay eng
dc.subject igg eng
dc.subject.ddc 660 | Technische Chemie ger
dc.title Flow-injection sandwich ELISA for bioprocess monitoring eng
dc.type Article
dc.type Text
dc.relation.issn 1463-9246
dc.relation.doi https://doi.org/10.1155/S1463924699000140
dc.bibliographicCitation.issue 4
dc.bibliographicCitation.volume 21
dc.bibliographicCitation.firstPage 121
dc.bibliographicCitation.lastPage 125
dc.description.version publishedVersion
tib.accessRights frei zug�nglich


Die folgenden Lizenzbestimmungen sind mit dieser Ressource verbunden:

Die Publikation erscheint in Sammlung(en):

Zur Kurzanzeige

 

Suche im Repositorium


Durchblättern

Mein Nutzer/innenkonto

Nutzungsstatistiken