Dynamic simulation and experimental validation of a two-phase closed thermosyphon for geothermal application

Zur Kurzanzeige

dc.identifier.uri http://dx.doi.org/10.15488/1831
dc.identifier.uri http://www.repo.uni-hannover.de/handle/123456789/1856
dc.contributor.author Ebeling, Johann-Christoph
dc.contributor.author Luo, Xing
dc.contributor.author Kabelac, Stephan
dc.contributor.author Luckmann, Sebastian
dc.contributor.author Kruse, Horst
dc.date.accessioned 2017-09-07T11:22:19Z
dc.date.available 2017-09-07T11:22:19Z
dc.date.issued 2017
dc.identifier.citation Ebeling, J.-C.; Luo, X.; Kabelac, S.; Luckmann, S.; Kruse, H.: Dynamic simulation and experimental validation of a two-phase closed thermosyphon for geothermal application. In: Psychology of Learning and Motivation - Advances in Research and Theory 67 (2017), S. 107-116. DOI: https://doi.org/10.1016/j.jppr.2017.05.002
dc.description.abstract The heat transfer performance of a vertical two-phase closed thermosyphon (TPCT) used in a geothermal heat pump was experimentally investigated. The TPCT is a vertical plain steel pipe with inner diameter of 114 mm and bored 368 m deep underground. Carbon dioxide (CO2) is used as working fluid. In the TPCT there is no condensation section. CO2 is condensed by the evaporator of the heat pump, flows into the head of the TPCT and runs down as a falling film along the inner wall of the pipe. For the heat transfer simulation in the TPCT, a quasi-dynamic model in which the mass transfer between the liquid and vapor phases as well as the conduction heat transfer from the surrounding soil towards the pipe is treated dynamically. However the film flow modeling is based on the Nusselt theory of film condensation. The comparison of the experimental data with the numerical simulation is presented and discussed. eng
dc.description.sponsorship BMWi/FKZ/03ET1050B
dc.language.iso eng
dc.publisher London : Academic Press Inc.
dc.relation.ispartofseries Psychology of Learning and Motivation - Advances in Research and Theory 67 (2017)
dc.rights CC BY-NC-ND 4.0 Unported
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subject Dynamic simulation eng
dc.subject Experimental validation eng
dc.subject Falling film evaporation eng
dc.subject Geothermal heat pump eng
dc.subject Geothermal thermosyphon eng
dc.subject Two-phase closed thermosyphon (TPCT) eng
dc.subject.ddc 530 | Physik ger
dc.title Dynamic simulation and experimental validation of a two-phase closed thermosyphon for geothermal application
dc.type Article
dc.type Text
dc.relation.issn 00797421
dc.relation.doi https://doi.org/10.1016/j.jppr.2017.05.002
dc.bibliographicCitation.volume 67
dc.bibliographicCitation.firstPage 107
dc.bibliographicCitation.lastPage 116
dc.description.version publishedVersion
tib.accessRights frei zug�nglich


Die Publikation erscheint in Sammlung(en):

Zur Kurzanzeige

 

Suche im Repositorium


Durchblättern

Mein Nutzer/innenkonto

Nutzungsstatistiken