Fracture Resistance of Repaired 5Y-PSZ Zirconia Crowns after Endodontic Access

Zur Kurzanzeige

dc.identifier.uri http://dx.doi.org/10.15488/14848
dc.identifier.uri https://www.repo.uni-hannover.de/handle/123456789/14967
dc.contributor.author Greuling, Andreas
dc.contributor.author Wiemken, Mira
dc.contributor.author Kahra, Christoph
dc.contributor.author Maier, Hans Jürgen
dc.contributor.author Eisenburger, Michael
dc.date.accessioned 2023-09-29T08:09:49Z
dc.date.available 2023-09-29T08:09:49Z
dc.date.issued 2023
dc.identifier.citation Greuling, A.; Wiemken, M.; Kahra, C.; Maier, H.J.; Eisenburger, M.: Fracture Resistance of Repaired 5Y-PSZ Zirconia Crowns after Endodontic Access. In: Dentistry Journal 11 (2023), Nr. 3, 76. DOI: https://doi.org/10.3390/dj11030076
dc.description.abstract This study analyzed the fracture load before and after a chewing simulation of zirconia crowns that were trepanned and repaired using composite resin. Overall, 3 groups with 15 5Y-PSZ crowns in each group were tested. For group A, the fracture load of the unmodified crowns was evaluated. For group B, the crowns were trepanned and repaired using composite resin, also followed by a fracture test. For group C, crowns were prepared like in group B but received thermomechanical cycling before the final fracture tests. Furthermore, scanning electron microscopy (SEM) and X-ray microscopy (XRM) analysis were performed for group C. The mean fracture loads and standard deviation were 2260 N ± 410 N (group A), 1720 N ± 380 N (group B), and 1540 N ± 280 N (group C). Tukey-Kramer multiple comparisons showed a significant difference between groups A and B (p < 0.01) and groups A and C (p < 0.01). After ageing, surface fissures were detected via SEM, but no cracks that reached from the occlusal to the inner side of the crown were detected via XRM. Within the limitations of this study, it can be stated that trepanned and composite-repaired 5Y-PSZ crowns show lower fracture loads than 5Y-PSZ crowns without trepanation. eng
dc.language.iso eng
dc.publisher Basel : MDPI
dc.relation.ispartofseries Dentistry Journal 11 (2023), Nr. 3
dc.rights CC BY 4.0 Unported
dc.rights.uri https://creativecommons.org/licenses/by/4.0
dc.subject chewing simulation eng
dc.subject endodontic access eng
dc.subject fracture load eng
dc.subject repaired crowns eng
dc.subject zirconia eng
dc.subject.ddc 610 | Medizin, Gesundheit
dc.title Fracture Resistance of Repaired 5Y-PSZ Zirconia Crowns after Endodontic Access eng
dc.type Article
dc.type Text
dc.relation.essn 2304-6767
dc.relation.doi https://doi.org/10.3390/dj11030076
dc.bibliographicCitation.issue 3
dc.bibliographicCitation.volume 11
dc.bibliographicCitation.firstPage 76
dc.description.version publishedVersion
tib.accessRights frei zug�nglich


Die Publikation erscheint in Sammlung(en):

Zur Kurzanzeige

 

Suche im Repositorium


Durchblättern

Mein Nutzer/innenkonto

Nutzungsstatistiken