Performance Evaluation of an Evacuated Tube Collector with a Low-Cost Diffuse Reflector

Zur Kurzanzeige

dc.identifier.uri http://dx.doi.org/10.15488/14537
dc.identifier.uri https://www.repo.uni-hannover.de/handle/123456789/14655
dc.contributor.author Schumann, Julian
dc.contributor.author Schiebler, Bert
dc.contributor.author Giovannetti, Federico
dc.date.accessioned 2023-08-24T07:52:20Z
dc.date.available 2023-08-24T07:52:20Z
dc.date.issued 2021
dc.identifier.citation Schumann, J.; Schiebler, B.; Giovannetti, F.: Performance Evaluation of an Evacuated Tube Collector with a Low-Cost Diffuse Reflector. In: Energies 14 (2021), Nr. 24, 8209. DOI: https://doi.org/10.3390/en14248209
dc.description.abstract In order to increase the overall solar energy gain of evacuated tube collectors, rear‐side reflectors are used. In this way, the otherwise unused incident radiation between the tubes can be reflected back to the absorber, and the performance of the collector can be improved. In this paper, the use of a low‐cost, diffusely reflecting, trapezoidal roof covering made from a galvanized metal sheet is investigated and compared to a high‐quality, specularly reflecting plane reflector made of aluminum. For this purpose, ray‐tracing analysis and TRNSYS simulations were carried out. In the ray‐tracing analysis, the experimentally determined zero‐loss collector efficiency η0 as well as the incident angle modifiers for each reflector can be reproduced with an error lower than 7.5%. Thermal system simulations show that the performance of both reflectors is comparable. The use of the low‐cost reflector leads to an increase in annual collector output of around 30% compared to an increase with the specular reflector of around 33%. Considering a typical domestic hot water system, both reflectors enable an increase in the solar annual yield of approx. 11%. eng
dc.language.iso eng
dc.publisher Basel : MDPI
dc.relation.ispartofseries Energies 14 (2021), Nr. 24
dc.rights CC BY 4.0 Unported
dc.rights.uri https://creativecommons.org/licenses/by/4.0
dc.subject Diffuse reflector eng
dc.subject Evacuated tube collector eng
dc.subject Ray tracing eng
dc.subject Solar thermal eng
dc.subject Specular reflector eng
dc.subject TRNSYS eng
dc.subject.ddc 621,3 | Elektrotechnik, Elektronik
dc.title Performance Evaluation of an Evacuated Tube Collector with a Low-Cost Diffuse Reflector eng
dc.type Article
dc.type Text
dc.relation.essn 1996-1074
dc.relation.doi https://doi.org/10.3390/en14248209
dc.bibliographicCitation.issue 24
dc.bibliographicCitation.volume 14
dc.bibliographicCitation.firstPage 8209
dc.description.version publishedVersion
tib.accessRights frei zug�nglich