Control and automatic alignment of the output mode cleaner of GEO 600

Zur Kurzanzeige

dc.identifier.uri http://dx.doi.org/10.15488/1418
dc.identifier.uri http://www.repo.uni-hannover.de/handle/123456789/1443
dc.contributor.author Prijatelj, M.
dc.contributor.author Grote, Hartmut
dc.contributor.author Degallaix, J.
dc.contributor.author Hewitson, M.
dc.contributor.author Hild, S.
dc.contributor.author Affeldt, Christoph
dc.contributor.author Freise, A.
dc.contributor.author Leong, J.
dc.contributor.author Lück, Harald
dc.contributor.author Strain, Kenneth A.
dc.contributor.author Wittel, H.
dc.contributor.author Willke, Benno
dc.contributor.author Danzmann, Karsten
dc.date.accessioned 2017-04-28T08:05:14Z
dc.date.available 2017-04-28T08:05:14Z
dc.date.issued 2010
dc.identifier.citation Prijatelj, M.; Grote, H.; Degallaix, J.; Hewitson, M.; Hild, S. et al.: Control and automatic alignment of the output mode cleaner of GEO 600. In: Journal of Physics: Conference Series 228 (2010), 12014. DOI: https://doi.org/10.1088/1742-6596/228/1/012014
dc.description.abstract The implementation of a mode cleaner at the output port of the GEO 600 gravitational wave detector will be part of the upcoming transition from GEO 600 to GEO-HF. Part of the transition will be the move from a heterodyne readout to a DC readout scheme. DC readout performance will be limited by higher order optical modes and control sidebands present at the output port. For optimum performance of DC readout an output mode cleaner (OMC) will clean the output beam of these contributions. Inclusion of an OMC will introduce new noise sources whose magnitudes needed to be estimated and for which new control systems will be needed. In this article we set requirements on the performance of these control systems and investigate the simulated performance of different designs. eng
dc.description.sponsorship Science and Technology Facilities Council (STFC)
dc.description.sponsorship BMBF
dc.description.sponsorship Max Planck Society (MPG)
dc.description.sponsorship State of Lower Saxony in Germany
dc.description.sponsorship European Gravitational Observatory (EGO)
dc.description.sponsorship DFG/SFB/Transregio 7
dc.language.iso eng
dc.publisher Bristol : IOP Publishing Ltd.
dc.relation.ispartofseries Journal of Physics: Conference Series 228 (2010)
dc.rights CC BY 3.0 Unported
dc.rights.uri https://creativecommons.org/licenses/by/3.0/
dc.subject Automatic alignment eng
dc.subject GEO 600 eng
dc.subject Gravitational wave detectors eng
dc.subject Higher order eng
dc.subject Noise source eng
dc.subject Optical modes eng
dc.subject Optimum performance eng
dc.subject Output beam eng
dc.subject Output ports eng
dc.subject Simulated performance eng
dc.subject Control systems eng
dc.subject Gravitational effects eng
dc.subject Remote control eng
dc.subject Gravity waves eng
dc.subject Gravitationswelle ger
dc.subject.classification Konferenzschrift ger
dc.subject.ddc 530 | Physik ger
dc.title Control and automatic alignment of the output mode cleaner of GEO 600 eng
dc.type Article
dc.type Text
dc.relation.issn 1742-6588
dc.relation.doi https://doi.org/10.1088/1742-6596/228/1/012014
dc.bibliographicCitation.volume 228
dc.bibliographicCitation.firstPage 12014
dc.description.version publishedVersion
tib.accessRights frei zug�nglich


Die folgenden Lizenzbestimmungen sind mit dieser Ressource verbunden:

Die Publikation erscheint in Sammlung(en):

Zur Kurzanzeige

 