Preliminary results in anterior cervical discectomy and fusion with an experimental bioabsorbable cage - clinical and radiological findings in an ovine animal model

Downloadstatistik des Dokuments (Auswertung nach COUNTER):

Daentzer, D.; Floerkemeier, T.; Bartsch, I.; Masalha, W.; Welke, B. et al.: Preliminary results in anterior cervical discectomy and fusion with an experimental bioabsorbable cage - clinical and radiological findings in an ovine animal model. In: SpringerPlus 2 (2013), Nr. 1 , S. 1-8. DOI: http://dx.doi.org/10.1186/2193-1801-2-418

Version im Repositorium

Zum Zitieren der Version im Repositorium verwenden Sie bitte diesen DOI: https://doi.org/10.15488/644

Zeitraum, für den die Download-Zahlen angezeigt werden:

Jahr: 
Monat: 

Summe der Downloads: 191




Kleine Vorschau
Zusammenfassung: 
Background: Bioabsorbable implants are not widely used in spine surgery. This study investigated the clinical and radiological findings after anterior cervical discectomy and fusion (ACDF) in an ovine animal model with an experimental bioabsorbable cage consisting of magnesium and polymer (poly-ε-caprolactone, PCL) in comparison to a tricortical bone graft as the gold standard procedure. Materials and Methods: 24 full-grown sheep had ACDF of C3/4 and C5/6 with an experimental bioabsorbable implant (magnesium and PCL) in one level and an autologous tricortical bone graft in the second level. The sheep were divided into 4 groups (6 sheep each). After 3, 6, 12, or 24 weeks postoperatively, the cervical spines were harvested and conventional x-rays of each operated segment were conducted. The progress of interbody fusion was classified according to a three-point scoring system. Results: There were no operation related complications except for one intraoperative fracture of the anterior superior iliac spine and two cases of screw loosening and sinking, respectively. In particular, no vascular, neurologic, wound healing or infectious problems were observed. According to the time of follow-up, both interbody fusion devices showed similar behaviour with increasing intervertebral osseointegration and complete arthrodesis in 10 of 12 (83.3%) motion segments after 24 weeks. Conclusions: The bioabsorbable magnesium-PCL cage used in this experimental animal study showed clinically no signs of incompatibility such as infectious or wound healing problems. The radiographic results regarding the osseointegration are comparable between the cage and the bone graft group.
Lizenzbestimmungen: CC BY 2.0 Unported
Publikationstyp: Article
Publikationsstatus: publishedVersion
Erstveröffentlichung: 2013
Die Publikation erscheint in Sammlung(en):Fakultät für Maschinenbau

Verteilung der Downloads über den gewählten Zeitraum:

Herkunft der Downloads nach Ländern:

Pos. Land Downloads
Anzahl Proz.
1 image of flag of Germany Germany 132 69,11%
2 image of flag of United States United States 25 13,09%
3 image of flag of China China 7 3,66%
4 image of flag of France France 5 2,62%
5 image of flag of Poland Poland 3 1,57%
6 image of flag of Netherlands Netherlands 3 1,57%
7 image of flag of India India 3 1,57%
8 image of flag of Hungary Hungary 2 1,05%
9 image of flag of Lithuania Lithuania 1 0,52%
10 image of flag of Iran, Islamic Republic of Iran, Islamic Republic of 1 0,52%
    andere 9 4,71%

Weitere Download-Zahlen und Ranglisten:


Hinweis

Zur Erhebung der Downloadstatistiken kommen entsprechend dem „COUNTER Code of Practice for e-Resources“ international anerkannte Regeln und Normen zur Anwendung. COUNTER ist eine internationale Non-Profit-Organisation, in der Bibliotheksverbände, Datenbankanbieter und Verlage gemeinsam an Standards zur Erhebung, Speicherung und Verarbeitung von Nutzungsdaten elektronischer Ressourcen arbeiten, welche so Objektivität und Vergleichbarkeit gewährleisten sollen. Es werden hierbei ausschließlich Zugriffe auf die entsprechenden Volltexte ausgewertet, keine Aufrufe der Website an sich.