Investigation of second harmonic generation and multispectral imaging as new contrast mechanisms in scanning laser optical tomography

Download statistics - Document (COUNTER):

Nolte, L.; Antonopoulos, G.C.; Heisterkamp, A.; Ripken, T.; Meyer, H.: Investigation of second harmonic generation and multispectral imaging as new contrast mechanisms in scanning laser optical tomography. In: Proceedings of SPIE 10499 (2018), 1049913. DOI: https://doi.org/10.1117/12.2289509

Repository version

To cite the version in the repository, please use this identifier: https://doi.org/10.15488/3353

Selected time period:

year: 
month: 

Sum total of downloads: 294




Thumbnail
Abstract: 
Scanning laser optical tomography (SLOT) is a 3D imaging technique, based on the principle of computed tomography to visualize samples up to magnitude of several centimeters. Intrinsic contrast mechanisms as absorption, scattering and autofluorescence provide information about the 3D architecture and composition of the sample. Another valuable intrinsic contrast mechanism is second harmonic generation (SHG), which is generated in noncentrosymmetric materials and commonly used to image collagen in biological samples. The angular dependence of the SHG signal, however, produces artifacts in reconstructed optical tomography datasets (OPT, SLOT). Thus, successful use of this intrinsic contrast mechanism is impaired. We investigate these artifacts by simulation and experiment and propose an elimination procedure that enables successful reconstruction of SHG-SLOT data. Nevertheless, in many cases specific labeling of certain structures is necessary to make them visible. Using multiple dyes in one sample can lead to crosstalk between the different channels and reduce contrast of the images. Also autofluorescence of the sample itself can account for that. By using multispectral imaging in combination with spectral unmixing techniques, this loss can be compensated. Therefore either a spectrally resolved detection path, or spectrally resolved excitation is required. Therefore we integrated a white supercontinuum light source in our SLOT-setup that enables a spectral selection of the excitation beam and extended the detection path to a four channel setup. This enables the detection of three fluorescence channels and one absorption channel in parallel, and increases the contrast in the reconstructed 3D images significantly. © COPYRIGHT SPIE. Downloading of the abstract is permitted for personal use only.
License of this version: Es gilt deutsches Urheberrecht. Das Dokument darf zum eigenen Gebrauch kostenfrei genutzt, aber nicht im Internet bereitgestellt oder an Außenstehende weitergegeben werden. Dieser Beitrag ist aufgrund einer (DFG-geförderten) Allianz- bzw. Nationallizenz frei zugänglich.
Document Type: BookPart
Publishing status: publishedVersion
Issue Date: 2018
Appears in Collections:Fakultät für Mathematik und Physik

distribution of downloads over the selected time period:

downloads by country:

pos. country downloads
total perc.
1 image of flag of Germany Germany 204 69.39%
2 image of flag of United States United States 43 14.63%
3 image of flag of China China 12 4.08%
4 image of flag of No geo information available No geo information available 4 1.36%
5 image of flag of United Kingdom United Kingdom 4 1.36%
6 image of flag of Israel Israel 3 1.02%
7 image of flag of Iran, Islamic Republic of Iran, Islamic Republic of 2 0.68%
8 image of flag of India India 2 0.68%
9 image of flag of Ireland Ireland 2 0.68%
10 image of flag of Switzerland Switzerland 2 0.68%
    other countries 16 5.44%

Further download figures and rankings:


Hinweis

Zur Erhebung der Downloadstatistiken kommen entsprechend dem „COUNTER Code of Practice for e-Resources“ international anerkannte Regeln und Normen zur Anwendung. COUNTER ist eine internationale Non-Profit-Organisation, in der Bibliotheksverbände, Datenbankanbieter und Verlage gemeinsam an Standards zur Erhebung, Speicherung und Verarbeitung von Nutzungsdaten elektronischer Ressourcen arbeiten, welche so Objektivität und Vergleichbarkeit gewährleisten sollen. Es werden hierbei ausschließlich Zugriffe auf die entsprechenden Volltexte ausgewertet, keine Aufrufe der Website an sich.

Search the repository


Browse