Tinne, N.; Nolte, L.; Antonopoulos, G.C.; Schulze, J.; Andrade, J. et al.: Three-dimensional imaging of intracochlear tissue by scanning laser optical tomography (SLOT). In: Proceedings of SPIE 9689 (2016), 96892H. DOI: https://doi.org/10.1117/12.2211066
Zusammenfassung: | |
The presented study focuses on the application of scanning laser optical tomography (SLOT) for non-destructive visualization of anatomical structures inside the human cochlea ex vivo. SLOT is a laser-based highly efficient microscopy technique, which allows for tomographic imaging of the internal structure of transparent large-scale specimens (up to 1 cm3). Thus, in the field of otology this technique is best convenient for an ex vivo study of the inner ear anatomy. For this purpose, the preparation before imaging comprises mechanically assisted decalcification, dehydration as well as optical clearing of the cochlea samples. Here, we demonstrate results of SLOT visualizing hard and soft tissue structures of the human cochlea with an optical resolution in the micrometer range using absorption and autofluorescence as contrast mechanisms. Furthermore, we compare our results with the method of X-ray micro tomography (micro-CT, μCT) as clinical gold standard which is based only on absorption. In general, SLOT can provide the advantage of covering all contrast mechanisms known from other light microscopy techniques, such as fluorescence or scattering. For this reason, a protocol for antibody staining has been developed, which additionally enables selective mapping of cellular structures within the cochlea. Thus, we present results of SLOT imaging rodent cochleae showing specific anatomical structures such as hair cells and neurofilament via fluorescence. In conclusion, the presented study has shown that SLOT is an ideally suited tool in the field of otology for in toto visualization of the inner ear microstructure. © 2016 SPIE. | |
Lizenzbestimmungen: | Es gilt deutsches Urheberrecht. Das Dokument darf zum eigenen Gebrauch kostenfrei genutzt, aber nicht im Internet bereitgestellt oder an Außenstehende weitergegeben werden. Dieser Beitrag ist aufgrund einer (DFG-geförderten) Allianz- bzw. Nationallizenz frei zugänglich. |
Publikationstyp: | BookPart |
Publikationsstatus: | publishedVersion |
Erstveröffentlichung: | 2016 |
Die Publikation erscheint in Sammlung(en): | Fakultät für Mathematik und Physik |
Pos. | Land | Downloads | ||
---|---|---|---|---|
Anzahl | Proz. | |||
1 | Germany | 194 | 80,17% | |
2 | United States | 23 | 9,50% | |
3 | China | 6 | 2,48% | |
4 | Russian Federation | 4 | 1,65% | |
5 | Ireland | 2 | 0,83% | |
6 | Netherlands | 1 | 0,41% | |
7 | Japan | 1 | 0,41% | |
8 | India | 1 | 0,41% | |
9 | United Kingdom | 1 | 0,41% | |
10 | Austria | 1 | 0,41% | |
andere | 8 | 3,31% |
Hinweis
Zur Erhebung der Downloadstatistiken kommen entsprechend dem „COUNTER Code of Practice for e-Resources“ international anerkannte Regeln und Normen zur Anwendung. COUNTER ist eine internationale Non-Profit-Organisation, in der Bibliotheksverbände, Datenbankanbieter und Verlage gemeinsam an Standards zur Erhebung, Speicherung und Verarbeitung von Nutzungsdaten elektronischer Ressourcen arbeiten, welche so Objektivität und Vergleichbarkeit gewährleisten sollen. Es werden hierbei ausschließlich Zugriffe auf die entsprechenden Volltexte ausgewertet, keine Aufrufe der Website an sich.