Comparison of Selective Laser Melted Titanium and Magnesium Implants Coated with PCL

Downloadstatistik des Dokuments (Auswertung nach COUNTER):

Matena, Julia; Petersen, Svea; Gieseke, Matthias; Teske, Michael; Beyerbach, Martin et al.: Comparison of Selective Laser Melted Titanium and Magnesium Implants Coated with PCL. In: International Journal of Molecular Sciences 16 (2015), Nr. 6, S. 13287-13301. DOI: https://doi.org/10.3390/ijms160613287

Version im Repositorium

Zum Zitieren der Version im Repositorium verwenden Sie bitte diesen DOI: https://doi.org/10.15488/1611

Zeitraum, für den die Download-Zahlen angezeigt werden:

Jahr: 
Monat: 

Summe der Downloads: 278




Kleine Vorschau
Zusammenfassung: 
Degradable implant material for bone remodeling that corresponds to the physiological stability of bone has still not been developed. Promising degradable materials with good mechanical properties are magnesium and magnesium alloys. However, excessive gas production due to corrosion can lower the biocompatibility. In the present study we used the polymer coating polycaprolactone (PCL), intended to lower the corrosion rate of magnesium. Additionally, improvement of implant geometry can increase bone remodeling. Porous structures are known to support vessel ingrowth and thus increase osseointegration. With the selective laser melting (SLM) process, defined open porous structures can be created. Recently, highly reactive magnesium has also been processed by SLM. We performed studies with a flat magnesium layer and with porous magnesium implants coated with polymers. The SLM produced magnesium was compared with the titanium alloy TiAl6V4, as titanium is already established for the SLM-process. For testing the biocompatibility, we used primary murine osteoblasts. Results showed a reduced corrosion rate and good biocompatibility of the SLM produced magnesium with PCL coating.
Lizenzbestimmungen: CC BY 4.0 Unported
Publikationstyp: Article
Publikationsstatus: publishedVersion
Erstveröffentlichung: 2015
Die Publikation erscheint in Sammlung(en):Fakultät für Maschinenbau

Verteilung der Downloads über den gewählten Zeitraum:

Herkunft der Downloads nach Ländern:

Pos. Land Downloads
Anzahl Proz.
1 image of flag of Germany Germany 204 73,38%
2 image of flag of United States United States 25 8,99%
3 image of flag of China China 10 3,60%
4 image of flag of Iran, Islamic Republic of Iran, Islamic Republic of 6 2,16%
5 image of flag of No geo information available No geo information available 5 1,80%
6 image of flag of Turkey Turkey 4 1,44%
7 image of flag of Czech Republic Czech Republic 4 1,44%
8 image of flag of Korea, Republic of Korea, Republic of 3 1,08%
9 image of flag of Australia Australia 3 1,08%
10 image of flag of Russian Federation Russian Federation 2 0,72%
    andere 12 4,32%

Weitere Download-Zahlen und Ranglisten:


Hinweis

Zur Erhebung der Downloadstatistiken kommen entsprechend dem „COUNTER Code of Practice for e-Resources“ international anerkannte Regeln und Normen zur Anwendung. COUNTER ist eine internationale Non-Profit-Organisation, in der Bibliotheksverbände, Datenbankanbieter und Verlage gemeinsam an Standards zur Erhebung, Speicherung und Verarbeitung von Nutzungsdaten elektronischer Ressourcen arbeiten, welche so Objektivität und Vergleichbarkeit gewährleisten sollen. Es werden hierbei ausschließlich Zugriffe auf die entsprechenden Volltexte ausgewertet, keine Aufrufe der Website an sich.