Establishing a link to given radiated emission limits during extending the frequency range above 1 GHz

Download statistics - Document (COUNTER):

Garbe, H.; Battermann, S.: Establishing a link to given radiated emission limits during extending the frequency range above 1 GHz. In: Advances in Radio Science 6 (2008), S. 303-306. DOI: https://doi.org/10.5194/ars-6-303-2008

Repository version

To cite the version in the repository, please use this identifier: https://doi.org/10.15488/1475

Selected time period:

year: 
month: 

Sum total of downloads: 149




Thumbnail
Abstract: 
Up to now most limits for radiated emission are given as values for the electrical field strength. Battermann, 2007 has shown that the frequency range extension for radiated emission measurements above 1 GHz generates a lot of problems while performing the test on a classical test site as depicted in Fig. 1. This paper will give a motivation to use an other measurand namely the total-radiated-power than electrical field strength by using alternative test sites like reverberation chambers, TEM-waveguides, Fully Anechoic Rooms (FAR) etc. Nevertheless most of the existing standards still specify electrical field strength limits. This paper will show how to set the parameters in the given algorithm to establish a link between measured total radiated power and equivalent electrical field values.
License of this version: CC BY 3.0 Unported
Document Type: Article
Publishing status: publishedVersion
Issue Date: 2008
Appears in Collections:Fakultät für Elektrotechnik und Informatik

distribution of downloads over the selected time period:

downloads by country:

pos. country downloads
total perc.
1 image of flag of Germany Germany 104 69.80%
2 image of flag of United States United States 24 16.11%
3 image of flag of China China 11 7.38%
4 image of flag of Taiwan Taiwan 1 0.67%
5 image of flag of Sweden Sweden 1 0.67%
6 image of flag of Netherlands Netherlands 1 0.67%
7 image of flag of Japan Japan 1 0.67%
8 image of flag of Indonesia Indonesia 1 0.67%
9 image of flag of United Kingdom United Kingdom 1 0.67%
10 image of flag of Australia Australia 1 0.67%
    other countries 3 2.01%

Further download figures and rankings:


Hinweis

Zur Erhebung der Downloadstatistiken kommen entsprechend dem „COUNTER Code of Practice for e-Resources“ international anerkannte Regeln und Normen zur Anwendung. COUNTER ist eine internationale Non-Profit-Organisation, in der Bibliotheksverbände, Datenbankanbieter und Verlage gemeinsam an Standards zur Erhebung, Speicherung und Verarbeitung von Nutzungsdaten elektronischer Ressourcen arbeiten, welche so Objektivität und Vergleichbarkeit gewährleisten sollen. Es werden hierbei ausschließlich Zugriffe auf die entsprechenden Volltexte ausgewertet, keine Aufrufe der Website an sich.

Search the repository


Browse