Calibration-measurement unit for the automation of vector network analyzer measurements

Downloadstatistik des Dokuments (Auswertung nach COUNTER):

Rolfes, I.; Will, B.; Schiek, B.: Calibration-measurement unit for the automation of vector network analyzer measurements. In: Advances in Radio Science 6 (2008), S. 27-30. DOI: https://doi.org/10.5194/ars-6-27-2008

Version im Repositorium

Zum Zitieren der Version im Repositorium verwenden Sie bitte diesen DOI: https://doi.org/10.15488/1455

Zeitraum, für den die Download-Zahlen angezeigt werden:

Jahr: 
Monat: 

Summe der Downloads: 169




Kleine Vorschau
Zusammenfassung: 
With the availability of multi-port vector network analyzers, the need for automated, calibrated measurement facilities increases. In this contribution, a calibrationmeasurement unit is presented which realizes a repeatable automated calibration of the measurement setup as well as a user-friendly measurement of the device under test (DUT). In difference to commercially available calibration units, which are connected to the ports of the vector network analyzer preceding a measurement and which are then removed so that the DUT can be connected, the presented calibrationmeasurement unit is permanently connected to the ports of the VNA for the calibration as well as for the measurement of the DUT. This helps to simplify the calibrated measurement of complex scattering parameters. Moreover, a full integration of the calibration unit into the analyzer setup becomes possible. The calibration-measurement unit is based on a multiport switch setup of e.g. electromechanical relays. Under the assumption of symmetry of a switch, on the one hand the unit realizes the connection of calibration standards like one-port reflection standards and two-port through connections between different ports and on the other hand it enables the connection of the DUT. The calibration-measurement unit is applicable for two-port VNAs as well as for multiport VNAs. For the calibration of the unit, methods with completely known calibration standards like SOLT (short, open, load, through) as well as self-calibration procedures like TMR or TLR can be applied. © Author(s) 2008.
Lizenzbestimmungen: CC BY 3.0 Unported
Publikationstyp: Article
Publikationsstatus: publishedVersion
Erstveröffentlichung: 2008
Die Publikation erscheint in Sammlung(en):Fakultät für Elektrotechnik und Informatik

Verteilung der Downloads über den gewählten Zeitraum:

Herkunft der Downloads nach Ländern:

Pos. Land Downloads
Anzahl Proz.
1 image of flag of Germany Germany 81 47,93%
2 image of flag of United States United States 36 21,30%
3 image of flag of China China 9 5,33%
4 image of flag of Israel Israel 5 2,96%
5 image of flag of Indonesia Indonesia 5 2,96%
6 image of flag of Sweden Sweden 3 1,78%
7 image of flag of Malaysia Malaysia 3 1,78%
8 image of flag of Czech Republic Czech Republic 3 1,78%
9 image of flag of No geo information available No geo information available 2 1,18%
10 image of flag of Russian Federation Russian Federation 2 1,18%
    andere 20 11,83%

Weitere Download-Zahlen und Ranglisten:


Hinweis

Zur Erhebung der Downloadstatistiken kommen entsprechend dem „COUNTER Code of Practice for e-Resources“ international anerkannte Regeln und Normen zur Anwendung. COUNTER ist eine internationale Non-Profit-Organisation, in der Bibliotheksverbände, Datenbankanbieter und Verlage gemeinsam an Standards zur Erhebung, Speicherung und Verarbeitung von Nutzungsdaten elektronischer Ressourcen arbeiten, welche so Objektivität und Vergleichbarkeit gewährleisten sollen. Es werden hierbei ausschließlich Zugriffe auf die entsprechenden Volltexte ausgewertet, keine Aufrufe der Website an sich.