Atomic clock comparisons with a 3e-16 uncertainty via geostationary satellites

Download statistics - Document (COUNTER):

Riedel, Franziska: Atomic clock comparisons with a 3e-16 uncertainty via geostationary satellites. Hannover : Gottfried Wilhelm Leibniz Universität, Diss., 2021, VIII, 138 S. DOI: https://doi.org/10.15488/11330

Selected time period:

year: 
month: 

Sum total of downloads: 263




Thumbnail
Abstract: 
Optical clocks are superior to all other clocks, reaching 1e-18 in their uncertainty. This makes them not only attractive for the field of fundamental research, like testing General Relativity or examining the variance of fundamental constants, but marks them also as potential candidates for the new definition of the second. An essential step towards that direction is the possibility to carry out comparisons of optical clocks at remote sites to have consistency checks of clocks constructed mostly independently by different groups. Satellite-based techniques offer the possibility of simultaneous comparisons over a large variety of baselines. Their instability, however, has been demonstrated to be in the low 1e-15 range at 1 d averaging time for most measurements. In case of two-way satellite time and frequency transfer (TWSTFT), the instability is limited by the modulation bandwidth of the signal. For this work, the full bandwidth of 20 Mchip/s of the commonly used TWSTFT equipment, a SATRE modem, is employed, providing a potential improvement of a factor of 20 with respect to the currently performed TWSTFT measurements for the time scale comparisons contributing to TAI.This technique is used in this work to compare five optical clocks and six microwave fountain clocks located at four different European metrology institutes simultaneously over a period of 26 d. In order to prepare this measurement, extensive studies on the SATRE modem are carried out and presented, and other aspects that need to be taken into account for TWSTFT measurements with low instabilities are discussed, such as atmospheric delays, geometric and relativistic effects and laboratory and roof station setups.The link instability of TWSTFT during the measurement campaign is presented, and compared to the instability of GPS Precise Point Positioning, that is implemented as an additional, independent comparisons technique for the campaign.Relative frequency differences of the optical and the fountain clocks are calculated. For that, a processing was introduced that combines phase and frequency data of different noise types and gaps. A respective estimator for the statistical uncertainty, based on the correlation on the data, is established. The results of both satellite-based techniques show good agreement with each other, and also clocks based on the same frequency transition agree within a 1-σ-uncertainty. The overall uncertainties obtained for TWSTFT are between 2.7e-16 and 3.5e-16 for the opticalclock comparisons. Limitations for the uncertainties of the measurements are discussed in detail, the available satellite-based techniques are evaluated with respect to their advantages and drawbacks for similar measurements in the future.
License of this version: CC BY 3.0 DE
Document Type: DoctoralThesis
Publishing status: publishedVersion
Issue Date: 2021
Appears in Collections:Fakultät für Mathematik und Physik
Dissertationen

distribution of downloads over the selected time period:

downloads by country:

pos. country downloads
total perc.
1 image of flag of China China 72 27.38%
2 image of flag of Germany Germany 64 24.33%
3 image of flag of United States United States 20 7.60%
4 image of flag of Netherlands Netherlands 13 4.94%
5 image of flag of Russian Federation Russian Federation 12 4.56%
6 image of flag of No geo information available No geo information available 10 3.80%
7 image of flag of Hong Kong Hong Kong 9 3.42%
8 image of flag of Turkey Turkey 6 2.28%
9 image of flag of Iran, Islamic Republic of Iran, Islamic Republic of 6 2.28%
10 image of flag of Czech Republic Czech Republic 6 2.28%
    other countries 45 17.11%

Further download figures and rankings:


Hinweis

Zur Erhebung der Downloadstatistiken kommen entsprechend dem „COUNTER Code of Practice for e-Resources“ international anerkannte Regeln und Normen zur Anwendung. COUNTER ist eine internationale Non-Profit-Organisation, in der Bibliotheksverbände, Datenbankanbieter und Verlage gemeinsam an Standards zur Erhebung, Speicherung und Verarbeitung von Nutzungsdaten elektronischer Ressourcen arbeiten, welche so Objektivität und Vergleichbarkeit gewährleisten sollen. Es werden hierbei ausschließlich Zugriffe auf die entsprechenden Volltexte ausgewertet, keine Aufrufe der Website an sich.

Search the repository


Browse